7-5
Theory of Operation
Pipelined Parallel Processing (P
3
)
Traditional RAID controller designs execute host commands sequentially.
Each command initiates a sequence of hardware activities that are
processed one after the other until the command is complete. If any of
these activities are delayed, hardware components must wait. These
delays compromise performance. DPTs P
3
technology addresses this
problem in five important areas:
Real-Time Control System P
3
technology can process a virtually
unlimited number of host commands in parallel. The SmartRAID V
Real-Time Control System (RTCS) breaks each command down into
sub-tasks that are then routed to one of the following hardware
processors on the controller:
DMA processor
XOR processor
SCSI or Fibre Channel interface.
Host Commands
DMA Engine
XOR Engine
SCSI / Fibre Channel
Interface
Controller CPU
Hardware Request Schedulers Each hardware processor has an
associated hardware request scheduler that coordinates its queued
requests and manages the queue so that all subtasks are processed
efficiently. The disk hardware request scheduler manages one request
queue for each disk drive attached to the controller. To achieve
maximum throughput from each drive, sorted disk queues are
maintained by grouping requests when possible. This results in an
increased number of read and write operations per drive.